    1. 液位計廠家,液位變送器廠家產(chǎn)品推薦
      天津國產(chǎn)壓力變送器,差壓變送器常見故障分析!
      信息來源: 差壓變送器生產(chǎn) | 2019-05-13 點擊量: 7954

         壓力變送器常見故障分析!西安華恒儀表制造有限公司為您介紹:

       
        Pressure transmitter common fault analysis!Xi'an Huaheng Instrument Manufacturing Co.,Ltd.
       
        一:無輸出
        One:No Output
       
        1、導(dǎo)壓管開關(guān)沒有打開;
        2、導(dǎo)壓管路堵塞;
        3、供電電源過低;
        4、供電電源接錯;
        5、儀表輸出回路故障;
        6、安全柵故障;
        7、表頭故障、無法顯示;
        8、內(nèi)部插件接觸不良;
        9、電路板故障
       
        1.The switch of the guide pipe is not opened;
        2.The guide pipe is blocked;
        3.The power supply is too low.
        4.Connection fault of power supply;
        5.Output circuit fault of instrument;
        6.Safety grid fault;
        7.Head failure,unable to display;
        8.Poor contact of internal plug-ins;
        9.Circuit Board Faults
       
        二、輸出過大
        Excessive Output
       
        1、導(dǎo)壓管中有殘存液體、氣體;
        2、電路板故障;
        3、負(fù)導(dǎo)壓管一次閥沒開或者是沒開全;
        4、負(fù)壓管泄露;
        5、安全柵故障;
        6、DCS量程設(shè)置過大;
       
        1.There are residual liquids and gases in the guide pipe;
        2.circuit board fault;
        3.negative guide pipe primary valve is not opened or not fully opened;
        4.negative pressure pipe leakage;
        5.safety grid fault;
        6.DCS range setting is too large;
       
        三、輸出過小
        Third,too small output
       
        1、正導(dǎo)壓管堵;
        2、平衡閥漏或者沒關(guān)死;
        3、電路板故障;
        4、正導(dǎo)壓管一次閥沒開或者是沒開全;
        5、正壓管泄露;
        6、安全柵故障;
        7、DCS量程設(shè)置過?。?/div>
       
        1.Plugging of positive pressure guide pipe;
        2.Leakage or not closing of balance valve;
        3.Circuit board fault;
        4.Primary valve of positive pressure guide pipe is not opened or not fully opened;
        5.Leakage of positive pressure pipe;
        6.Safety grid fault;
        7.DCS range setting is too small;
       
        四、輸出不穩(wěn)定
        IV.Output instability
       
        1、導(dǎo)壓管中有殘存液體、氣體;
        2、被測介質(zhì)有波動;
        3、輸出回路中有接觸不良或斷續(xù)短路;
        4、接線松動;
        5、內(nèi)部接插件接觸不良;
        6、壓力傳感器損壞;
        7、電路中有多處接地;
       
        1.There are residual liquids and gases in the guide pipe;
        2.There are fluctuations in the measured medium;
        3.There are bad contacts or intermittent short circuit in the output circuit;
        4.loose wiring;
        5.bad contacts of internal connectors;
        6.damage of pressure sensors;
        7.there are many grounding points in the circuit;
      ?
      掃一掃.廠家定制電話,
      RM新时代平台网址-首页

    2. <em id="r84rl"><button id="r84rl"><noscript id="r84rl"></noscript></button></em>
    3. <samp id="r84rl"><samp id="r84rl"></samp></samp>
      1. <em id="r84rl"><button id="r84rl"><noscript id="r84rl"></noscript></button></em>
      2. <samp id="r84rl"><samp id="r84rl"></samp></samp>
        1. RM新时代投资安全吗 RM新时代是正规平台吗 新时代官方下载 新时代游戏官方网站 新时代RM官方网站下载